Wall -mounted boiler manufacturers: Detailed introduction of common sense of wall -mounted stoves


Published:

2023-01-03

Wall -mounted boiler manufacturers: Detailed introduction of common sense of wall -mounted stoves

Wall -mounted boiler manufacturers: Detailed introduction of common sense of wall -mounted stoves

Wall -mounted boiler manufacturers: Maintenance methods for common problems of wall -hung boilers

1. Environmental temperature controller failure

Failure problem: ambient temperature controller failure. The actual fault phenomenon and solutions are mainly the following:

① Flowing fire, the main controller reports the case, showing the failure encoding of heating or boiling water controller. Solution: If you connect to short -circuit or lamp lines in the distribution line, you can remove the transmission line and the lighting line again.

Qcob5MI3Ru2h1dmJuLX87g.jpg

② Temperature sensor lead. Solution: If the electrode connection cable shestor in the power distribution line is damaged and the short -circuit failure is disassembled; if the temperature sensor is damaged, the temperature sensor is disassembled;

2. Although the open type runs normally, the water storage tank sets the water

Fault problem: water storage tanks. The actual fault phenomenon and solutions are mainly the following:

① The full -automatic water replenishment valve has dirty stuck and can not block drinking water, so that drinking water is injected into heating water and raised water. Solution: If there is a dirty thing that accumulates the rubber membrane with a fully automatic water replenishment valve, the sealing difference is eliminated, and the dirt is eliminated;

② The internal structure of the plate heat exchanger seeps water and causes water. Solution: Disassembling plate heat exchanger.

③ The heating system is too large to run with water tanks. Solution: assemble the inverse valve on the road of heating pipes to replace the convenient open water storage tank.

3. Although the closed type runs normally, the pressure of work continues to rise

Fault problem: The work pressure of the hydraulic meter continues to rise, and the pressure reduction valve seepage is long -term. The actual fault phenomenon and solutions are mainly the following:

① The manual hydration valve itself cannot block drinking water due to mechanical failure, so that drinking water enters the heating system. Solution: Eliminate the dirt of the manual hydration valve seal rubber to replace the new seal rubber.

② The internal structure of the plate heat exchanger's internal structural water seepage or the internal structure of the integrated system of the waterway. Solution: Disassembling board heat exchanger or all sewer integration systems.

4. Heating heating is fast, but the heat pipe radiator is not cold

Failure: Immediately, the environmental temperature set is set, but the heat pipe radiator is not cold, and the working temperature cannot rise. The actual fault phenomenon and solutions are mainly the following:

① There are a large amount of gas in the heating system that are not exhausted. Solution: exhaust the air in the system;

② The heating system is blocked, causing a slow water circulation system. Solution: Clear the filtering device of the heating system;

③ There are many regulators that only open a little, and the water flow is slow. Solution: Effectively turn on the regulator;

④ The heating system is very large, and the pump selection is insufficient. Solution: Improve one more centrifugal pump to increase the circulation system power;

⑤ Destruction of the pump. Solution: Disassembling pump or disassembling a separate heart pump;

⑥ The operating voltage of the control board exports the work voltage of the centrifugal water pump is abnormal. Solution: Disassembling control board;

The power gear adjustment of the pump is unscientific. Solution: adjust the scientific and reasonable gear of centrifugal water pump;

⑧ Inlet valve is not calibrated. Solution: Calibrate the intake valve.

Wall -mounted boiler manufacturers: I will no longer do too much explanation. If you need the purchase of wall -mounted boilers or installation matters, we can entrust our wall -hung boiler manufacturers to do it.

 